Colorimetric and turbidimetric analysis of endotoxins using the absorbance detection mode
Torn between a colorimetric or turbidimetric LAL assay? Whichever path you take, BMG LABTECH’s absorbance readers deliver dependable results every time.
The VANTAstar® is the latest addition to our family. This compact multi-mode microplate reader was conceived for ease-of-use and flexibility and ensures effortless detection setup for a simplified data generation. Equipped with our patented dual LVF Monochromators™ system, filters, UV/vis spectrometer, and Enhanced Dynamic Range technology, it can cover a wide range of applications in basic research and life science.

The VANTAstar is an upgradable multi-mode microplate reader compatible with all plate formats up to 384 wells. The Enhanced Dynamic Range (EDR) technology, a fast full-plate auto-focus, and luminescence cross-talk reduction make assay detection easier than ever and manual optimization superfluous.
With its Atmospheric Control Unit for gas control, temperature incubation, multiple shaking options, well scan and reagent injectors with heater and stirrer, the VANTAstar supports all live cell-based assays. The VANTAstar is also available with only filter-based detection. Check here more details about the VANTAstar F.
The VANTAstar comes now with Voyager, BMG LABTECH´s new microplate reader control interface. Designed to remove complexity while maximising flexibility, Voyager makes data acquisition more intuitive than ever.
The VANTAstar is for research use only.


BMG LABTECH microplate readers are built to be robust and reliable. No calibration of optical components is required. Recommended maintenance includes plate carrier offset adjustments, cleaning optical components, software/firmware updates, and routine performance checks.
BMG LABTECH offers flexible maintenance plans to ensure long-term performance. Costs depend on the chosen plan. Contact us using the service contract form.
Yes, comprehensive technical support and training services are available to assist users in maximizing the instrument’s capabilities. Contact us to find out more.
You can find detailed product information, specifications, and available configurations on the VANTAstar product page. For purchase options, quotes, or personalized recommendations, please send a sales request directly.
You can request a quote for additional filters via our filter request form.
Reader manuals are included with every instrument. If you no longer have your manual, please use our manual request form to obtain a copy.
The software is included with every reader and can be installed on as many computers as needed. You can find it on a USB stick included with the manual. If you’ve misplaced the USB stick, we can provide a download link. Contact our software support.
Yes, the software for your VANTAstar is fully compatible with Windows 11. To ensure smooth operation on Windows 11, or if you need help with installation or have compatibility questions, please contact our software support.
Costs vary depending on the chosen configuration. Contact us for a personalized quote.
Yes, we provide comprehensive How-To Notes that explain common detection parameters, how they influence your results, and practical tips for optimizing measurements. You can find these resources on our How-To notes page.
Delivery times depend on model availability, configuration and your location. For accurate lead times, please send a general request on the contact page directly.
Torn between a colorimetric or turbidimetric LAL assay? Whichever path you take, BMG LABTECH’s absorbance readers deliver dependable results every time.
Unlocking Nature’s Timekeepers. Learn how to read the internal clock of organisms and how to decode life’s 24-hour rhythm at the molecular level using a microplate reader.
Streamline your workflow and double your insights: multiplexing cellular signal responses of multiple second messengers in a single measurement saves valuable time and conserves reagents.
Perform the PYROSTAR ES-F/Plate LAL test your way— BMG LABTECH readers support both turbidimetric and nephelometric evaluation for maximum flexibility.
Are you a fan of the monocyte activation test for endotoxin tests, but would like to speed up the testing process? Read here how the LumiMAT test and BMG LABTECH readers can support you.
Do you want to make your MIC measurements more efficient and automated? Find out here how BMG LABTECH microplate readers can support you in this task.
Fluorescence intensity (incl. FRET)
Fluorescence polarization
Luminescence (flash and glow) - incl. BRET
Time-resolved fluorescence
TR-FRET
UV/vis absorbance spectra
Top and bottom reading
Endpoint and kinetic
Sequential multi-excitation
Sequential multi-emission
Spectral scanning (fluorescence, luminescence, absorbance)
Ratiometric measurements
Well scanning
6- to 384-well plates, user-definable
LVis Plate with 16 low volume microspots (2 μL)
Robot compatible
High energy xenon flash lamp
Low-noise photomultiplier tube
CCD spectrometer
Dual Linear Variable Filter (LVF) Monochromators™
Linear Variable Dichroic Mirror
Separates ex & em LVF Monochromators
Optical filters:
Ex and em slides hold up to 5 filters each
LVF Monochromators + optical filters
Use one for ex and the other for em
UV/Vis absorbance spectrometer: Full spectra or 8 distinct wavelengths in < 1 sec/well
Filters
FI, LUM, TRF, FP, TR-FRET: 240 - 740 nm
LVF Monochromators™
FI, LUM: 320 - 740 nm
Linear Variable Dichroic
340 - 740 nm
Spectrometer
ABS: 220 - 1000 nm; wavelength precision: ≤ 0.5 nm
FI filters
(top)
< 0.5 pM (< 10 amol/well FITC, 384sv, 20 μL).
FI filters
(bottom)
< 2.5 pM (< 125 amol/well FITC, 384g, 50 μL).
FI monochromator
(top)
< 0.8 pM (< 16 amol/well FITC, 384sv, 20 μL).
FI monochromator
(bottom)
< 3.5 pM (< 175 amol/well FITC, 384g, 50 μL).
Dynamic Range: 8 decades in a single measurement.
FP
< 1.2 mP SD at 1 nM FITC (384sv, 20 μL).
HTRF®
(black and white microplates)
Reader Control Kit (Eu) after 18h (384sv, 20 μL).
Delta F > 700% (High Calibrator).
Delta F > 25% (Low Calibrator).
TRF
< 30 fM europium (< 2.4 amol/well, 384, 80 μL).
LUM
< 0.8 pM (< 15 amol/well ATP, 384sv, 20 μL).
Dynamic range: 8 decades in a single measurement.
ABS with spectrometer
Selectable spectral resolution: 1, 2, 5, and 10 nm.
OD range: 0 to 4 OD; photometric resolution: 0.001 OD.
Accuracy: < 1% at 2 OD.
Precision: < 0.5% at 1 OD and < 0.8% at 2 OD.
Linearity: ≤ 0.8% at 2.0 OD.
Flying mode (1 flash)
9 sec (96), 16 sec (384)
Linear, circular and double-circular with user-definable time and speed
+4 °C above ambient up to 45 °C or 60 °C
Minimum condensation concept: the upper heating plate of the incubation chamber operates at +0.5 °C than the lower plate, heated optic system
Multi-user reader control (SMART Control and Voyager) and data analysis software (MARS).
FDA 21 CFR Part 11 compliance available with SMART Control and MARS.
Integrated fluorophore library.
Width: 35 cm, depth: 52 cm, height: 36 cm; weight: 27 kg
Excitation and emission slides for up to 4 filters each for monochoromator units (VANTAstar), and for up to 5 filters each for filter-only units (VANTAstar F)
Top and bottom: free-air optical light path guided by motor-driven mirrors and dichroics
Automatic focal height adjustment (0.1 mm resolution)
Up to 2 reagent injectors
Individual injection volumes for each well: 3 to 500 μL (optionally up to 1 mL)
Variable injection speed up to 420 μL/s
Reagent back flushing
Heater and stirrer plate
Dimensions: width: 13 cm, depth: 31 cm, height: 26 cm; weight: 6 kg
Sample capacity: sixteen separate microdrop wells for 2 µL samples; one standard cuvette position for up to 1 mL samples
Quality Control Internal Standards (optional): four NIST traceable optical density filters (approximate values of 0.1, 0.3, 0.6 and 1.0 OD); one holmium oxide filter for wavelength accuracy
Dimensions: conforms to SBS standards for microplates
Microplate incubator and shaker
Actively regulates O2 and CO2 - 1-20%
Excitation and emission filters
Upgrades to include options such as additional detection modes, reagent injectors, extended temperature control, etc. are available
Please contact your local representative for more information
LOD = 3 x SD (20 blanks) / slope (6 pt std curve)
96 = 96-well microplates
384sv = 384-well small volume microplates
384g = 384-well glass bottom microplates
The VANTAstar is for research use only.